Bloc d’alimentation électrique
  retour

 

Type III C-A
netzteil-3C-AAbbildung groß
 

Instructions d'installation

Dimensions maßzeichnung

3-D Dessin Download:
IGS       STEP

Alimentation électrique pour le type d'accessoire III C-A
Bloc d’alimentation électrique, au courant réglé
Convient aux freins magnétiques en poudre et à hystérésis

Données techniques
Input
90 – 264 VAC, 47 – 63 Hz
Output Voltage
0 - 60 V DC
Output Power 80 W max.
Output Current 0 - 2 A with user-adjustable current limit
Overload Protection Short circuit or overload: unit switches off, attempts to switch on within a short period of time.
Current Ramp Adjustable 0-Full load from 0-5 seconds
Operating Temperature -15°C to +40°C
Control Voltage 0-10V DC
Additional Fixed Voltage 24 V DC (Power ultrasonic probe)
Display 2 line x 8 character backlit LCD
Temperaturüberwachung Die Einheit schaltet bei thermischer Überlast ab und schaltet nach Abkühlung wieder ein.
Power Failure Reset Control settings are retained in non-volatile memory. When power is restored unit returns to previous operating state.
Safety EN 60950-1
Emission EN61000-3-2 Klasse A, EN55022B Klasse B, FCC Teil 15 Class B
Directives Low voltage directive 2006/95/EC ROHS Directive 2011/65/EU
Ripple & Noise 1 %
Full Load Efficiency 90 %
Switching Frequency 100 kHz


 

 

 

Type III C-Enetzteil_C-EAbbildung groß

Installation Instructions Bedienungsanleitung

Dimensions Bedienungsanleitung

Alimentation intégrée Type III C-E
Alimentation pour montage sur panneau, adapté à la norme DIN sur rail 35 mm

Convient aux freins magnétiques en poudre et à hystérésis

Données techniques

Input 90 - 264 V AC, 47 - 63 Hz
Output Voltage

0 - 60 V DC
Output Power 80 W max.
Output Current 0 - 2 A with user-adjustable current limit
Overload Protection Short circuit or overload: unit switches off, attempts to switch on within a short period of time.
Current Ramp Adjustable 0-Full load from 0-5 seconds
Operating Temperature -15°C to +40°C
Control Voltage 0 - 10 V DC
Additional Fixed Voltage 24 V DC (Power ultrasonic probe)
Display 2 line x 8 character backlit LCD
Temperature Control Unit will switch off during thermal overload, and switch back on again after cool down.
Power Failure Reset Control settings are retained in non-volatile memory. When power is restored unit returns to previous operating state.
Safety EN 60950-1
Emission EN61000-3-2 Klasse A, EN55022B Klasse B, FCC part 15 Class B
Directives Low voltage directive 2006/95/EC ROHS Directive 2011/65/EU
Ripple & Noise 1 %
Full Load Efficiency 90 %
Switching Frequency 100 kHz

powerblockAbbildung groß
Dimensions

PowerBlock 2

powerblockAlimentation à courant régulé basé sur la technologie de microcontrôleur.
Contrôle du courant de sortie précise, indépendante de la température de la bobine. Haute protection contre les transitoires, conduisant à une grande fiabilité dans les environnements industriels.

Voltage électrique 1 - 10 volt

Uniquement pour des freins à poudre magnétique!

Données techniques

  PowerBlock 2
Tension d’entrée (V AC/DC) 24
Max. tension de sortie (Amp) 2
Output load (Ω) 4 - 20
Max. power consumption (VA) 70
Remote voltage control (VDC) 0 - 10
Ambient temperature (°C) +10 - +40