Power supply unit
  back

 

Typ III C-A
netzteil-3C-AAbbildung groß
 

Installation instructions

Dimensions maßzeichnung

3-D Drawing Download:
IGS       STEP

Power Supply for Attachment Type III C-A
current controlled power supply, suitable for Magnetic Powder Brakes and Current Controlled Hysteresis Brakes

Technical Data
Input
90 – 264 VAC, 47 – 63 Hz
Output Voltage
0 - 60 V DC
Output Power 80 W max.
Output Current 0 - 2 A with user-adjustable current limit
Overload Protection Short circuit or overload: unit switches off, attempts to switch on within a short period of time.
Current Ramp Adjustable 0-Full load from 0-5 seconds
Operating Temperature -15°C to +40°C
Control Voltage 0-10V DC
Additional Fixed Voltage 24 V DC (Power ultrasonic probe)
Display 2 line x 8 character backlit LCD
Temperaturüberwachung Die Einheit schaltet bei thermischer Überlast ab und schaltet nach Abkühlung wieder ein.
Power Failure Reset Control settings are retained in non-volatile memory. When power is restored unit returns to previous operating state.
Safety EN 60950-1
Emission EN61000-3-2 Klasse A, EN55022B Klasse B, FCC Teil 15 Class B
Directives Low voltage directive 2006/95/EC ROHS Directive 2011/65/EU
Ripple & Noise 1 %
Full Load Efficiency 90 %
Switching Frequency 100 kHz


 

 

 

Typ III C-Enetzteil_C-EAbbildung groß

Installation Instructions Bedienungsanleitung

Dimensions Bedienungsanleitung

Power Supply for Installation Type III C-E
Power supply unit for control cabinet installation, suitable for DIN rail 35 mm

suitable for Magnetic Powder Brakes and Current Controlled Hysteresis Brakes

Technical Data

Input 90 - 264 V AC, 47 - 63 Hz
Output Voltage

0 - 60 V DC
Output Power 80 W max.
Output Current 0 - 2 A with user-adjustable current limit
Overload Protection Short circuit or overload: unit switches off, attempts to switch on within a short period of time.
Current Ramp Adjustable 0-Full load from 0-5 seconds
Operating Temperature -15°C to +40°C
Control Voltage 0 - 10 V DC
Additional Fixed Voltage 24 V DC (Power ultrasonic probe)
Display 2 line x 8 character backlit LCD
Temperature Control Unit will switch off during thermal overload, and switch back on again after cool down.
Power Failure Reset Control settings are retained in non-volatile memory. When power is restored unit returns to previous operating state.
Safety EN 60950-1
Emission EN61000-3-2 Klasse A, EN55022B Klasse B, FCC part 15 Class B
Directives Low voltage directive 2006/95/EC ROHS Directive 2011/65/EU
Ripple & Noise 1 %
Full Load Efficiency 90 %
Switching Frequency 100 kHz

PowerBlock 2

powerblockAbbildung groß

Dimensions Maßangaben

PowerBlock 2

Current Regulated Power Supply based on microcontroller technology.
Accurate current output control, independent of coil temperature. High protection against transients, leading to high reliability in industrial environments.

Control electric voltage connection 0 - 10 volt

Only suitable for Magnetic Particle Brakes
and Clutches
!

Technical Data

powerblock
  PowerBlock 2
Input voltage (V AC/DC) 24
Max. output current (Amp) 2
Output load (Ω) 4 - 20
Max. power consumption (VA) 70
Remote voltage control (VDC) 0 - 10
Ambient temperature (°C) -10 - +40

back