Power supply unit
  back

 

Abbildung groß
Type II C


NetzteilAbbildung groß
Tyep II C-A
with digital power displa

Typ II C / C-A power supply, current controlled  

Technical Data
Input voltage
or changeable
with bridge BR3
U = 230 V AC 10% 50 Hz
U = 110 V AC + 15/-6% 50-60 Hz
Output voltage
Output current
or changeable with bridge BR2
UA = 0-37 V DC
IA = 0-2A, 0-0,8 A, 0-0,6A, 0-0,4A
Overload protection At short circuit or overload the unit switches off and tries to switch on again within short time periods.
Characteristics of control The output current is controlled by potentiometer or control voltage input. It is independant from temperature deviations and load.
Current ramp There can be used a current ramp with the switch in switch off situation. The ramp time can be adjusted with max. 5 sec.
Operating temperature -15°C to +40°C
Input fuse 1,6 A sensible
Control tension 0-10 V DC
Limitation of input current Resistor with negative koefficientv
Temperature control Unit will switch off at thermic overload. Switch on again after cool down period and after switch off input tension.
Safety of unit as perEN 60950
Disturbings depending
on load
as perEN 55022 B

Installation instructions
 Dimensions
3D-Drawin   IGS     STEP


einbaunetzteil-typ2c-e
Abbildung großdimensions

Power Supply for Installation Typ II C-E
Power Supply Unit for mounting into control cabinets, usable for DIN-rail 35 mm

Technical Data

Input voltage
or changeable
with bridge BR3
U = 240V AC 10% 50 Hz
U = 100 V AC + 15/-6% 50-60 Hz
Output voltage
Output current
or changeable with bridge BR2
UA = 0 - 37V DC
IA = 0 - 0,2A, 0 - 0,3 A ,0 - 0,4A, 0 - 0,6A, 0 - 0,8A, 0 - 1,2A, 0 - 1,6A,0 - 2,0A
Overload protection At short circuit or overload the unit switches off and tries to switch on again within short time periods.
Characteristics of control The output current is controlled by potentiometer or control voltage input. It is independant from temperature deviations and load.
Current ramp There can be used a current ramp with the switch in switch off situation. The ramp time can be adjusted with max. 5 sec.
Operating temperature -15°C to +40°C
Input fuse 3,15 A microfuse
Control tension 0-10V DC
Limitation of input current Resistor with negative koefficientv
Temperature control Unit will switch off at thermic overload. Switch on again after cool down period and after switch off input tension.
Safety of unit as perEN 60950
Disturbings depending
on load
as perEN 55022 B

Installation instruction




powerblockAbbildung groß
dimensions

PowerBlock2

powerblockCurrent Regulated Power Supply based on microcontroller technology.
Accurate current output control, independent of coil temperature. High protection against transients, leading to high reliability in industrial environments.

Technical Data

  PowerBlock 2
Input voltage (V AC/DC) 24
Max. output current (Amp) 2
Output load (Ω) 4 - 20
Max. power consumption (VA) 70
Remote voltage control (VDC) 0 - 10
Ambient temperature (°C) +10 - +40