Input voltage
or changeable
with bridge BR3 |
U = 230 V AC
10% 50 Hz
U = 110 V AC + 15/-6% 50-60 Hz |
Output voltage
Output current
or changeable with bridge BR2 |
UA = 0-37 V DC
IA = 0-2A, 0-0,8 A, 0-0,6A, 0-0,4A |
| Overload protection |
At short circuit
or overload the unit switches off and tries to switch on again within
short time periods. |
| Characteristics of control |
The output current is controlled by potentiometer
or control voltage input. It is independant from temperature deviations
and load. |
| Current ramp |
There can be used a current ramp with
the switch in switch off situation. The ramp time can be adjusted
with max. 5 sec. |
| Operating temperature |
-15°C to +40°C |
| Input fuse |
1,6 A sensible |
| Control tension |
0-10 V DC |
| Limitation of input current |
Resistor with negative koefficientv |
| Temperature control |
Unit will switch off at thermic overload.
Switch on again after cool down period and after switch off input
tension. |
| Safety of unit |
as perEN 60950 |
Disturbings depending
on load |
as perEN 55022 B |